Meth decontamination is not a deep clean with a stronger chemical. It is a sequence: assess, screen or test, remove contaminated materials where required, wash, treat, rinse and verify. The products matter, but only when they are used inside a documented process that matches the property, the contamination and the rules in your state or territory.
This guide is for Australian restoration contractors, cleaning businesses moving into remediation, property managers and inspectors who want to understand the products involved. It explains where surface screening kits fit, what a prewash does, how the Actichem MethSan two-part system is put together, and the PPE and record-keeping habits that should sit around it. Product details come from the current Restoration Warehouse product pages. It is not a substitute for training, the product label or the safety data sheet.
Know the rules before you quote
Requirements for meth-affected properties differ across Australia. The national Clandestine Drug Laboratory Remediation Guidelines (Australian Government, 2011) are a common reference point, and state and territory health departments and local councils may set their own expectations for assessment, remediation and clearance. Some jobs will involve a separate assessor, an environmental consultant or a council notice.
Before you price a job, confirm:
- who is responsible for the assessment and for clearance testing;
- what standard or guideline the property owner, insurer or council expects you to work to;
- whether any materials, such as carpet, underlay or soft furnishings, are to be removed rather than cleaned; and
- what documentation you need to hand over at the end.
Getting this clear up front protects your business and the client. It also stops a cleaning job quietly becoming an unpriced remediation job.
Meth testing: where screening kits fit
Meth testing usually happens at more than one point: before work to understand whether residue is present and where, and after work to check the outcome. There is an important difference between a field screening test and laboratory analysis.
A meth test kit for surface screening gives a quick presence or absence result on site. The Narco Screen Methamphetamine Testing Kit stocked by Restoration Warehouse includes:
- 10 MMC forensic methamphetamine screening tests;
- 10 buffer solution bottles;
- 10 sampling swabs;
- 10 test templates; and
- an instruction sheet, with a safety data sheet provided for the buffer solution.
Its product page lists uses in residential and commercial buildings, vehicles, boats and confined spaces, including pre- and post-remediation screening.
Use screening to help decide where to look harder and where to focus work. Where a job needs a formal result for a landlord, insurer, council or sale, check whether laboratory-analysed samples taken by a qualified assessor are required. A screening result on its own may not be accepted as clearance.
Practical screening habits
- Follow the kit instructions exactly, including the template area and swab technique.
- Record each sample location on a floor plan, with a photo.
- Sample consistently before and after work, so you are comparing like with like.
- Change gloves between samples to avoid carrying residue from one area to another.
Step one: removal and prewash
Before any chemical treatment, many jobs involve removing contaminated items and heavily soiled materials that are not to be kept. Your scope and the applicable guideline should guide what stays and what goes.
On the surfaces that remain, a prewash removes general soil, grease and film so the main treatment can reach the surface. Actichem MethSan Prewash (DR634) is the pre-wash detergent and emulsifier in the MethSan range, available in 5L and 20L. The MethSan Part A page states that Actichem recommends prewashing the contaminated area with MethSan PreWash before heavy-duty applications.
Think of prewash as the step that makes the rest work. Kitchens, rangehoods, light switches, door frames and other high-touch surfaces often carry a film that a treatment chemical will struggle to get through on its own.
Step two: the MethSan two-part treatment
The core of meth cleaning with this system is MethSan Part A combined with one of two Part B boosters. Part A is never used alone, and the boosters are not interchangeable with other chemicals.
MethSan Part A
Actichem MethSan Part A (DR610) is described as a potentiated hydrogen peroxide decontaminant for the main wash stage of methamphetamine and illicit drug contamination remediation. According to its product page:
- it uses a potentiated hydrogen peroxide blend with super-wetting agents to help penetrate porous building materials;
- it must be combined with either MethSan Part B Fog Boost or MethSan Part B Foam Boost, and must not be mixed with any other products;
- the mixing rate is 4 parts MethSan A to 1 part MethSan B, equal to 200 ml of Part B per 1 L of Part A;
- the prepared solution should be used within 12 hours of mixing;
- treated surfaces must stay wet for 4 hours, with rewetting where required and regular agitation with a brush or pad;
- surfaces are rinsed with clean water at the end;
- the listed pH is 5.5 to 6, and it carries a Warning safety classification; and
- it is for trained professional operators, with appropriate PPE and respiratory protection, and you should test an inconspicuous area for chemical sensitivity and dye stability first.
It comes in 5L and 20L packs. The page also lists complementary antimicrobial action against bacteria, viruses and mould.
Choosing Fog Boost or Foam Boost
The Part B booster you choose sets the application method.
- MethSan Part B Fog Boost (DR636, 5L) increases oxidising activity and enables ULV cold-fog application. Its page describes fine droplets for coverage and penetration of porous or difficult surfaces. Fogging suits complex rooms, ceiling spaces and areas that are hard to reach by hand. See the foggers and ULV machines range and check any fogger against the MethSan instructions before use.
- MethSan Part B Foam Boost (DR638, 5L) increases hydrogen peroxide oxidising activity and produces a clinging foam. Its page describes better wetting and contact on vertical and porous surfaces, and it is applied with professional foam-generating equipment.
Many crews will use both on the same project: foam on walls, cabinetry and detailed surfaces where dwell time is the challenge, and fog for coverage in spaces that are difficult to treat by hand. Whichever you use, the 4-hour wet contact time is the part that most often goes wrong. Plan labour so someone is on site to rewet and agitate surfaces rather than walking away after the first application.
You can see the full range together in the meth and biohazard cleaning category.
Step three: rinse, dry and verify
After the contact period, rinse treated surfaces with clean water as directed and let the property dry. Then return to testing. Screen the same locations you sampled before work, using the same method, and record the results alongside your photos.
If results are not where they need to be, the answer is usually more process, not a different chemical: another prewash on stubborn film, more agitation, better contact time or removal of a material that cannot be effectively treated. Where formal clearance is required, the assessor’s method and results are what count.
PPE and site set-up
Meth decontamination exposes workers to residue and to the treatment chemicals themselves. The MethSan Part A page calls for appropriate personal protective and respiratory equipment, operated by trained professionals. Base your PPE selection on the safety data sheet for each product and your own risk assessment, not on habit.
Typical considerations include:
- Body protection. Disposable coveralls such as Ezy Consumables Disposable Coveralls Type 5 & 6 help keep residue off clothing. Our coveralls guide explains the type ratings.
- Hand protection. Use gloves suited to the chemicals in use, and change them often. Our nitrile glove guide covers everyday disposable gloves and their limits.
- Respiratory protection. Select this from the SDS, particularly for fogging. Do not assume a particulate mask is suitable for chemical mists or vapours.
- Containment and access. Control who enters the property during treatment, signpost the area and keep the space ventilated as the label directs once fogging is complete.
If you are new to reading chemical documentation, our guide to reading an Australian safety data sheet is a useful starting point.
Records that protect your business
Remediation work is often reviewed by people who were not on site: landlords, insurers, councils and future buyers. Good records are part of the job.
- Pre-work screening or test results, with a sampling plan.
- A scope that lists materials removed and surfaces treated.
- Product names, batch numbers where available, mixing times and application methods.
- Contact-time records showing when surfaces were wetted, rewetted and rinsed.
- Post-work screening or test results, using the same locations.
- Before and after photos.
Putting your meth decontamination kit together
A practical starting kit covers each stage of the job:
| Stage | Products at Restoration Warehouse |
|---|---|
| Screening | Narco Screen Methamphetamine Testing Kit (10 tests) |
| Prewash | Actichem MethSan Prewash (5L, 20L) |
| Main treatment | Actichem MethSan Part A (5L, 20L) |
| Application booster | MethSan Part B Fog Boost (5L) or Foam Boost (5L) |
| Fogging equipment | ULV foggers range (check against MethSan instructions) |
| PPE | Disposable coveralls, suitable gloves, SDS-selected respiratory protection |
Meth decontamination rewards crews who follow the process every time. Confirm the rules, screen and record, prewash, treat with the right booster and contact time, rinse, then verify.