Fiberlock RECON Smoke Odour Sealer UltraWhite Fire Smoke Odour Blocker Encapsulating Coating 18.9L
Select Section
Overview
Intro:
Fiberlock RECON Smoke Odour Sealer UltraWhite is a water based encapsulating coating designed for fire and smoke restoration. It permanently seals residual smoke odours and stains on structural surfaces while maintaining a breathable finish.
Key Benefits:
- Permanently encapsulates smoke odours in building materials
- Blocks stain bleed through on treated surfaces
- Maintains permeability without trapping moisture
- Reduces long term odour re-emission under changing conditions
- Improves restoration outcomes after fire damage
- Suitable for a wide range of structural substrates
Applications:
- Fire and smoke damage restoration projects
- Residential and commercial building interiors
- Wall cavities and concealed structural areas
- HVAC systems and ductwork
- Industrial and institutional restoration sites
- Areas affected by persistent smoke contamination
Features:
- Water based and non flammable formulation
- OdourLock encapsulation technology
- Highly permeable breathable coating
- Bonds to most common building substrates
- Suitable for fiberglass lined and unlined ductwork
- Meets NFPA 90A and NFPA 90B requirements
- Can be applied with brush or airless spray equipment
- Roller application not recommended
- UltraWhite finish for improved surface coverage visibility
- Tintable up to 2 oz universal liquid colourant per gallon
- Excellent stain blocking performance
- Designed for interior use only
- Final step in full odour management system
Surface Preparation:
- Surface must be thoroughly cleaned, dry and sound before application
- Recommended cleaning with RECON Heavy Duty Cleaner or Extreme Duty Cleaner
- Follow with odour neutralisation using RECON Extreme Duty Odour Counteractant
- Apply sealer only after complete cleaning and drying
Application Method:
- Brush: synthetic, nylon or polyester bristle
- Airless spray pressure: 2200 to 3000 PSI
- Spray tip range: 0.017 to 0.023
- Apply evenly and generously for full encapsulation
- Two coats may be required on porous or heavily stained surfaces
- Roller application not recommended
Coverage:
- Smooth surfaces: 200 to 400 square feet per gallon
- Porous surfaces: 100 to 200 square feet per gallon
Drying Times:
- Touch dry: 30 minutes at 70°F and 50 percent RH
- Recoat time: 4 hours at 70°F and 50 percent RH
- Minimum 24 hours before topcoating
Topcoating Requirements:
- Light sanding and cleaning required before topcoat
- Use 100 percent acrylic latex coating only
- Eggshell sheen or higher required
- Do not use enamel, alkyd or oil based coatings
- Test patch recommended prior to full application
Safety and Handling:
- Store between 10°C and 32°C
- Do not apply below 50°F or above 15 percent surface moisture content
- Ensure adequate ventilation during application
- Use NIOSH approved respirator when spraying
- Clean tools with warm soapy water before drying
- Interior use only
Why Choose This Product:
Selected for professional fire restoration work where permanent smoke odour encapsulation and stain blocking are required across structural surfaces and HVAC systems in demanding environments.
SPECIFICATIONS:
- Product type: smoke odour sealer encapsulating coating
- Brand: Fiberlock
- Product name: RECON Smoke Odour Sealer UltraWhite
- Volume: 18.9 litres
- Base: water based
- Flammability: non flammable
- Colour: UltraWhite, tintable up to 2 oz universal liquid colourant per gallon
- Application method: brush or airless spray only
- Spray pressure: 2200 to 3000 PSI
- Spray tip size: 0.017 to 0.023
- Coverage: 200 to 400 ft2 per gallon (smooth surfaces), 100 to 200 ft2 per gallon (porous surfaces)
- Drying time: 30 minutes touch dry at 70°F 50% RH
- Recoat time: 4 hours at 70°F 50% RH
- Topcoat time: minimum 24 hours
- Compatibility: drywall, masonry, timber, wall cavities, HVAC ductwork (fiberglass lined and unlined), porous and sealed substrates
- Standards: NFPA 90A and NFPA 90B compliant
- Roller use: not recommended
- Temperature range: 10°C to 32°C storage, minimum application 50°F
- Moisture limit: maximum 15 percent surface moisture